PLC program control operation instructions:
1. Set button (SET)
2. Add buttons
3. Reduce the button
4. Reset/manual forced refueling button (RESET)
Indicator description:
1. Oil pump working indicator
2. Oil pump stop indicator
technical parameter:
Power supply voltage: input voltage range 20-28VAC
Power consumption: maximum power consumption 3W
Working temperature: -40-85℃
Oil pump power: <100w
Timer setting method:
Setting method | first step | Press the set button for 3 seconds | Enter the running time T1 setting (the work light flashes quickly, 2 times per second) | Press the plus or minus key to change the number, long press the plus or minus key to quickly change the value |
Second step | Press the set key | Enter stop time T2 setting (STOP light flashes quickly, 2 times per second) | Press the plus or minus key to change the number, long press the plus or minus key to quickly change the value | |
Remarks |
Function Description:
1. The working time of the oil pump can be set from 1-9999 seconds;
2. The rest time of the oil pump can be set from 1-9999 minutes;
3. With manual and automatic functions, manual function: after pressing the manual button, the oil pump will function until the button is released; automatic function: cycle work according to the set time parameter;
4. Power failure memory function: when the power is off, the stop time will be recorded. The next time the power is turned on, the timing will continue from the last stop time. When the power is turned off during work, the next power on will restart from the set working time;
5. Signal output: high and low level.
Add:No. 1, Building 45b, North Chuangrong Industrial City, Yucheng Sub-district, Yuhuan City, Zhejiang Province
Zip:317600
Tel:0576-87234521
Fax:0576-87234522
Contact person: Manager Zhao
Mobile phone no.:13967670889
Email:office@kaitianyeya.com
Web:www.kaitianyeya.com
Copyright © Yuhuan Kaitian Hydraulic Lubrication Equipment Co., Ltd. 浙ICP备16006032号 Power:300.cn